Figure 5: Valve-in-valve implantation within bioprosthetic valves. Left coronary artery injection in lateral view (a) shows its relation to the bioprosthetic valve before its interrogation using a high pressure 22 mm balloon (b) across the valve. A Melody valve is expanded within the bioprosthetic valve, which acts as the landing zone (c). Final pulmonary arteriogram in cranial projection (d) shows absence of regurgitation

Figure 5: Valve-in-valve implantation within bioprosthetic valves. Left coronary artery injection in lateral view (a) shows its relation to the bioprosthetic valve before its interrogation using a high pressure 22 mm balloon (b) across the valve. A Melody valve is expanded within the bioprosthetic valve, which acts as the landing zone (c). Final pulmonary arteriogram in cranial projection (d) shows absence of regurgitation