Year : 2018
| Volume
: 11 | Issue : 1 | Page
: 109 |
|
Cost-effectiveness analysis of devices for closure of patent ductus arteriosus |
|
KM Krishnamoorthy, Arun Gopalakrishnan
Department of Cardiology, Sree Chitra Tirunal Institute of Medical Sciences and Technology, Trivandrum, Kerala, India
Click here for correspondence address and
email
Date of Web Publication | 18-Jan-2018 |
|
|
 |
|
How to cite this article: Krishnamoorthy K M, Gopalakrishnan A. Cost-effectiveness analysis of devices for closure of patent ductus arteriosus. Ann Pediatr Card 2018;11:109 |
How to cite this URL: Krishnamoorthy K M, Gopalakrishnan A. Cost-effectiveness analysis of devices for closure of patent ductus arteriosus. Ann Pediatr Card [serial online] 2018 [cited 2022 May 18];11:109. Available from: https://www.annalspc.com/text.asp?2018/11/1/109/223541 |
Sir,
The paper by El-Saiedi et al. is greatly appreciated for performing cost-effectiveness analysis of different devices for occlusion of patent ductus arteriosus (PDA) in children.[1] Including “regular” PDA occlude (ADO I) in a similar study would be interesting. It is generally considered cheaper. Aortic protrusion with ADO I is less than with ADO II.[2] When effectiveness alone is considered, ADO I was found to be the device of choice for PDA >3 mm with good success;[3] although, it was before the advent of ADO II. Comparison of ADO I, II and ADO II additional sizes showed that ADO I was convenient for medium- and large-sized PDA.[4]
Thank you,
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References | |  |
1. | El-Saiedi SA, El Sisi AM, Mandour RS, Abdel-Aziz DM, Attia WA. Cost-effectiveness analysis of different devices used for the closure of small-to-medium-sized patent ductus arteriosus in pediatric patients. Ann Pediatr Cardiol 2017;10:144-51.  [ PUBMED] |
2. | Liddy S, Oslizlok P, Walsh KP. Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices. Catheter Cardiovasc Interv 2013;82:253-9.  [ PUBMED] |
3. | Brunetti MA, Ringel R, Owada C, Coulson J, Jennings JM, Hoyer MH, et al. Percutaneous closure of patent ductus arteriosus: A multiinstitutional registry comparing multiple devices. Catheter Cardiovasc Interv 2010;76:696-702.  [ PUBMED] |
4. | Baspinar O, Irdem A, Sivasli E, Sahin DA, Kilinc M. Comparison of the efficacy of different-sized amplatzer duct occluders (I, II, and II AS) in children weighing less than 10 kg. Pediatr Cardiol 2013;34:88-94.  [ PUBMED] |

Correspondence Address: Prof. K M Krishnamoorthy Department of Cardiology, Sree Chitra Tirunal Institute of Medical Sciences and Technology, Trivandrum, Kerala India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/apc.APC_131_17

|
|
|
|
 |
 |
|
|